Test environment running 7.6.6

Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Tomographic image analysis and processing to simulate micro-petrophysical experiments

Research Projects

Organizational Units

Journal Issue

Abstract

We present a description of our departments work flow that utilises X-ray micro-tomography in the observation and prediction of physical properties of porous rock. These properties include fluid flow, dissolution/deposition, fracture mapping, and mechanical processes, as well as measurement of three-dimensional (3D) morphological attributes such as pore/grain size and shape distributions, and pore/grain connectivity. To support all these areas there is a need for well integrated and parallel research programs in hardware development, structural description and physical property modelling. Since we have the ability to validate simulation with physical measurement, (and vice versa), an important part of the integration of all these techniques is calibration at every stage of the work flow. For example, we can use high-resolution scanning electron microscopy (SEM) images to verify or improve our sophisticated segmentation algorithm based on image grey-levels and gradients. The SEM can also be used to obtain sub-resolution porosity information estimated from tomographic grey-levels and texture. Comparing experimental and simulated mercury intrusion porosimetry can quantify the effective resolution of tomograms and the accuracy of segmentation. The foundation of our calibration techniques is a robust and highly optimised 3D to 3D image-based registration method. This enables us to compare the tomograms of successively disturbed (e.g., dissolved, fractured, cleaned,...) specimens with an original undisturbed state. A two-dimensional (2D) to 3D version of this algorithm allows us to register microscope images (both SEM and quantitative electron microscopy) of prepared 2D sections of each specimen. This can assist in giving a multimodal assessment of the specimen.

Description

Citation

Source

Book Title

Developments in X-Ray Tomography VII

Entity type

Publication

Access Statement

License Rights

Restricted until