Test environment running 7.6.6

Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

The discrete Radon transform: A more efficient approach to image reconstruction?

Loading...
Thumbnail Image

Date

Journal Title

Journal ISSN

Volume Title

Publisher

Access Statement

Research Projects

Organizational Units

Journal Issue

Abstract

The Radon transform and its inversion are the mathematical keys that enable tomography. Radon transforms are defined for continuous objects with continuous projections at all angles in [0,π). In practice, however, we pre-filter discrete projections taken at a discrete set of angles and reconstruct a discrete object. Since we are approximating a continuous transform, it would seem that acquiring more projections at finer projection resolutions is the path to providing better reconstructions. Alternatively, a discrete Radon transform (DRT) and its inversion can be implemented. Then the angle set and the projection resolution are discrete having been predefined by the required resolution of the tomogram. DRT projections are not necessarily evenly spaced in [0, π), but are concentrated in directions which require more information due to the discrete square [or cubic] grid of the reconstruction space. A DRT, by design, removes the need for interpolation, speeding up the reconstruction process and gives the minimum number of projections required, reducing the acquisition time and minimizing the required radiation dose. This paper reviews the concept of a DRT and demonstrates how they can be used to reconstruct objects from X-ray projections more efficiently in terms of the number of projections and to enable speedier reconstruction. This idea has been studied as early as 1977 by Myron Katz. The work begun by Katz has continued and many methods using different DRT versions have been proposed for tomographic image reconstruction. Here, results using several of the prominent DRT formalisms are included to demonstrate the different techniques involved. The quality and artifact structure of the reconstructed images are compared and contrasted with that obtained using standard filtered back projection.

Description

Citation

Source

Book Title

Developments in X-Ray Tomography VI

Entity type

Publication

Access Statement

License Rights

Restricted until