Test environment running 7.6.6

Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Influence of screw to joint distance on articular subsidence in tibial-plateau fractures

Loading...
Thumbnail Image

Date

Journal Title

Journal ISSN

Volume Title

Publisher

Abstract

Background: Tibial-plateau fractures with depressed osteochondral fragments have a high incidence of articular subsidence post reduction. Locking plates aim to prevent this via ‘raft’ screws below the subchondral bone. However, differences in plate design and patient anatomy result in variability of screw position in relation to the fragments they are designed to support. We evaluate the effect of screw placement and articular subsidence with this fracture pattern. Methods: A retrospective cohort study of operatively treated tibial-plateau fractures with free osteochondral fragments was performed to determine if screw placement was correlated with articular subsidence. Primary outcome was the relationship between screw to joint distance and articular subsidence. Secondary outcomes were whether bicortical fixation, presence of bone graft, fracture characteristics and patient age was correlated with articular subsidence. Results: Sixty-eight of 309 tibial-plateau fractures had depressed osteochondral fragments (22%). The average thickness of these fragments was 10.2 mm. Fractures with raft screws placed closer to the joint than the thickness of the osteochondral fragment were less likely to subside (1.8 versus 3.4 mm; P = 0.02). The proportion of fractures with no radiographic subsidence was also greater in this cohort versus fractures with distal screw placement (33% versus 8%; P = 0.02). Articular comminution (P = 0.04) and female patients aged over 65 years (P = 0.03) were associated with increased articular subsidence. Conclusion: Fractures fixed with screws closer to the joint than the thickness of the osteochondral fragment were correlated with less articular subsidence. The ‘screw-joint distance’ may help guide screw placement intra-operatively.

Description

Citation

Source

ANZ Journal of Surgery

Book Title

Entity type

Access Statement

License Rights

Restricted until