Test environment running 7.6.6

Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Recovery of accurate T2 from historical 1.5 tesla proton density and T2-weighted images

Loading...
Thumbnail Image

Journal Title

Journal ISSN

Volume Title

Publisher

Abstract

Objective To determine accurate quantitative transverse relaxation times (T2) using retrospective clinical images and apply it to examine 7-year changes in multiple sclerosis (MS) brain. Methods A method for T2 mapping from retrospective proton density (PD) and T2-weighted fast spin echo images was recently introduced, but requires measurement of flip angles. We examined whether 1.5 T flip angle variation in brain can be predicted, thus enabling T2 analysis of historical PD and T2-weighted images without a concurrent flip angle map. After method validation in healthy volunteers, retrospective longitudinal T2 analysis was performed in 14 MS subjects over seven years. Changes in patient T2 values were compared with brain atrophy, T2 lesion load and disability score in MS. Results Similar flip angle maps across volunteers enabled retrospective T2 from PD and T2-weighted images even when different refocusing angles were used. Over seven years, significant T2 changes of 2–4% were observed when using T2 modelling and the 7-year effect size for globus pallidus T2 was 0.56, which was more significant than brain atrophy. No significant T2 results were found when using exponential fit, which cannot account for refocusing angle variation. Moreover, change is T2 in globus pallidus and internal capsule correlated with MS disability score over time when using T2 modelling. Conclusions Accurate quantitative T2 can be extracted from standard clinical 1.5 T MRI exams that include PD and T2-weighted imaging even when no flip angle map is available. This method was applied retrospectively to examine seven year changes in MS.

Description

Citation

Source

Magnetic Resonance Imaging

Book Title

Entity type

Access Statement

License Rights

Restricted until