Test environment running 7.6.6

Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

An evaluation of bubble-CPAP in a neonatal unit in a developing country

Loading...
Thumbnail Image

Date

Journal Title

Journal ISSN

Volume Title

Publisher

Abstract

To describe the implementation of bubble-CPAP in a referral hospital in a developing country and to investigate: the feasibility of nurses implementing bubble-CPAP and the impact of bubble-CPAP on need for mechanical ventilation and mortality. Retrospective evaluation of prospectively collected data from two time periods: 18 months before and 18 months after the introduction of bubble-CPAP. The introduction of bubble-CPAP was associated with a 50 per cent reduction in the need for mechanical ventilation; from 113 of 1106 (10.2 per cent) prior to bubble-CPAP to 70 of 1382 (5.1%) after introduction of CPAP (χ2, p<0.001). In the 18 months prior to bubble-CPAP there were 79 deaths (case fatality of 7.1 per cent). In the 18 months after bubble-CPAP there were 74 deaths (CF 5.4 per cent), relative risk: 0.75 (0.55-1.02, χ2, p=0.065). Nurses could safely apply bubble-CPAP after 1-2 months of on-the-job training. Equipment for Bubble-CPAP cost 15 per cent of the cost of the cheapest mechanical ventilator. The introduction of bubble-CPAP substantially reduced the need for mechanical ventilation, with no difference in mortality. In models of neonatal care for resource-limited countries, bubble-CPAP may be the first type of ventilatory support that is recommended. Its low cost and safety when administered by nurses makes it ideal for this purpose. Bubble-CPAP has the potential for being available at even lower cost than the current commercially available bubble systems used in this study.

Description

Keywords

Citation

Source

Journal of Tropical Pediatrics

Book Title

Entity type

Access Statement

License Rights

Restricted until