Test environment running 7.6.6

Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Volume status and volume responsiveness in postoperative cardiac surgical patients

Abstract

Background: The best strategy to identify patients in whom fluid loading increases cardiac output (CO) following cardiac surgery remains debated. This study examined the utility of a calculated mean systemic filling pressure analogue (Pmsa) and derived variables to explain the response to a fluid bolus. Methods: The Pmsa was calculated using retrospective, observational cohort data in the early postoperative period between admission to the intensive care unit and extubation within 6 hours. The venous return pressure gradient (VRdP) was calculated as Pmsa − central venous pressure. Concurrent changes induced by a fluid bolus in the ratio of the VRdP over Pmsa, the volume efficiency (Evol), were studied to assess fluid responsiveness. Changes between Pmsa and derived variables and CO were analysed by Wilcoxon rank-sum test, hierarchial clustering and multiple linear regression. Results: Data were analysed for 235 patients who received 489 fluid boluses. The Pmsa increased with consecutive fluid boluses (median difference [range] 1.3 [0.5-2.4] mm Hg, P =.03) with a corresponding increase in VRdP (median difference 0.4 [0.2-0.6] mm Hg, P =.04). Hierarchical cluster analysis only identified Evol and the change in CO within one cluster. The multiple linear regression between Pmsa and its derived variables and the change in CO (overall r2 =.48, P <.001) demonstrated the best partial regression between the continuous change in CO and the concurrent Evol (r =.55, P <.001). Conclusion: The mean systemic filling Pmsa enabled a comprehensive interpretation of fluid responsiveness with volume efficiency useful to explain the change in CO as a continuous phenomenon.

Description

Citation

Source

Acta Anaesthesiologica Scandinavica

Book Title

Entity type

Access Statement

License Rights

Restricted until