Test environment running 7.6.6

Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Prospective evaluation of blood coagulability and effect of treatment in patients with stroke using rotational thromboelastometry

Abstract

Background Stroke is the second largest cause of death worldwide. Abnormalities in hemostasis play an important role in the pathophysiology of ischemic stroke (IS). These hemostatic defects can be detected using rotational thromboelastometry (ROTEM) as a global method of measuring coagulation.This study assessed the effects of IS on blood hypercoagulability using ROTEM method, before and subsequent to therapeutic interventions. Methods In a prospective observational cohort study, whole blood coagulation using ROTEM, along with full blood count and standard coagulation tests, were compared between patients with IS and an age-matched control group of healthy volunteers. Further assessment took place at 2-4 hours and at 24 hours in the stroke group after therapy to assess the effects of therapeutic intervention. Results Seventy-two patients with IS were age-matched to 71 healthy subjects. Clotting time (CT) INTEM (P =.01) and maximum clot firmness (MCF) INTEM (P =.02) were significantly different between stroke patients at baseline and healthy subjects, but this difference disappeared when controlled for by smoking status. There was no association between ROTEM parameters and time from stroke symptom onset or stroke severity as reflected in The National Institute of Health Stroke Scale score. Significant but small changes in the values of MCF-EXTEM, clot formation time (CFT) EXTEM, and alpha-EXTEM CT were observed after therapeutic intervention (thrombolysis or aspirin treatment). Conclusions ROTEM testing does not seem to detect a hypercoagulable state in patients with IS. Nonetheless, some ROTEM parameters had a small change after antiplatelet therapy or thrombolysis.

Description

Citation

Source

Journal of Stroke and Cerebrovascular Diseases

Book Title

Entity type

Access Statement

License Rights

Restricted until