Impurity flow measurements at DIII-D using a coherence imaging spectrometer

Loading...
Thumbnail Image

Date

Authors

Weber, T R
Porter, G. D.
Meier, Eric T
Allen, S L
Howard, John

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier

Abstract

This work describes C2+ emission (CIII 465 nm) and flow measurements from the divertor region of a L-mode, lower-single-null plasma in DIII-D. The measurements use a coherence imaging spectrometer capable of making snapshot 2D C2+ flow measurements in the