Accurate measurement of the 12.6 GHz clock transition in trapped 171Yb+ ions
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
We have measured the frequency of the 171Yb+ 12.6 GHz MF = 0-5-0 ground state hyperfine clock transition in buffer gas-cooled ion clouds confined in two similar, but not identical, linear Paul traps. After correction for the known differences between the two ion traps, including significantly different second-order Doppler shifts, the frequencies agree within an uncertainty of less than 2 parts in 1013. Our best value, based on an analytic model for the second-order Doppler shift, for the frequency of the clock transition of an isolated ion at zero temperature, velocity, electric field and magnetic field, is 12642812118.466 ±0.002 Hz.
Description
Keywords
Citation
Collections
Source
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control