Test environment running 7.6.6

Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

NEW PUB FOR [Chris van Weel] - [Validity of spirometric testing in a general practice population of patients with chronic obstructive pulmonary disease (COPD)]

Loading...
Thumbnail Image

Date

Journal Title

Journal ISSN

Volume Title

Publisher

Abstract

Objective: To investigate the validity of spirometric tests performed in general practice. Method: A repeated within subject comparison of spirometric tests with a "gold standard" (spirometric tests performed in a pulmonary function laboratory) was performed in 388 subjects with chronic obstructive pulmonary disease (COPD) from 61 general practices and four laboratories. General practitioners and practice assistants undertook a spirometry training programme. Within subject differences in forced expiratory volume in 1 second and forced vital capacity (ΔFEV1 and ΔFVC) between laboratory and general practice tests were measured (practice minus laboratory value). The proportion of tests with FEV1 reproducibility <5% or <200 ml served as a quality marker. Results: Mean ΔFEV1 was 0.069 l (95% CI 0.054 to 0.084) and ΔFVC 0.081 l (95% CI 0.053 to 0.109) in the first year evaluation, indicating consistently higher values for general practice measurements. Second year results were similar. Laboratory and general practice FEV1 values differed by up to 0.5 l, FVC values by up to 1.0 l. The proportion of non-reproducible tests was 16% for laboratory tests and 18% for general practice tests (p = 0.302) in the first year, and 18% for both in the second year evaluation (p = 1 .000). Conclusions: Relevant spirometric indices measured by trained general practice staff were marginally but statistically significantly higher than those measured in pulmonary function laboratories. Because of the limited agreement between laboratory and general practice values, use of these measurements interchangeably should probably be avoided. With sufficient training of practice staff the current practice of performing spirometric tests in the primary care setting seems justifiable.

Description

Keywords

Citation

Source

Thorax

Book Title

Entity type

Access Statement

License Rights

Restricted until