Towards testing of a second-generation bladed receiver
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
A bladed receiver design concept is presented which offers a >2% increase in overall receiver efficiency after considering spillage, reflection, emission and convection losses, based on an integrated optical-thermal model, for a design where the working fluid is conventional molten salt operating in the standard 290-565°C temperature range. A novel testing methodology is described, using air and water to test the receiver when molten salt facilities are not available. Technoeconomic analysis shows that the receiver could achieve a 4 AUD/MWhe saving in levelised cost of energy, but only if the bladed receiver design can be implemented at no additional cost.