Test environment running 7.6.6

Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Multifocal pupillography in early age-related macular degeneration

Loading...
Thumbnail Image

Date

Authors

Sabeti, Faran
Maddess, Ted
Essex, Rohan
Saikal, Aiasha
James, Andrew
Carle, Corinne

Journal Title

Journal ISSN

Volume Title

Publisher

Lippincott Williams & Wilkins

Abstract

PURPOSE: To investigate the potential of multifocal pupillographic objective perimetry to assess changes in retinal function with clinical severity of age-related macular degeneration (AMD). METHODS: Pupil responses were recorded from 40 subjects with AMD and 23 normal control subjects (mean ± SD age, 71.3 ± 5.1 years). Age-related macular degeneration subjects were classified according to the Age-Related Eye Disease Study (AREDS) classification system and allocated into one of four AMD severity groups. Three multifocal pupillographic objective perimetry stimulus variants that were identical in luminance but varied in spatiotemporal sequence were used. In one of the three protocols, stimuli were presented with a pedestal flicker for 266 milliseconds at 15 Hz. RESULTS: On average, response amplitudes demonstrated a significant change in sensitivity with progression from early-stage (0.32 ± 0.08 dB, t = 3.88) to late-stage (-1.60 ± 0.12 dB, t = -12.7) age-related macular degeneration. Response delays followed a similar trend with the longest delays in AREDS4 (57.2 ± 1.9 milliseconds, t = 29.5). Ring analysis identified the largest mean effect on responses within the central 6 degrees of fixation. The NewStimuli protocol achieved the best diagnostic accuracy across all severity groups with area under the curve values of 0.85 ± 0.066 (AREDS1), 0.908 ± 0.085 (AREDS2), 0.929 ± 0.040 (AREDS3), and 1.0 ± 0.0 (AREDS4). CONCLUSIONS: The mean effect of AMD on contraction amplitudes and response delays reflected the severity of disease, and the NewStimuli protocol achieved good diagnostic accuracy across all AMD severity groups. Multifocal pupillographic objective perimetry may potentially be a useful method in monitoring progression of AMD and assessing change in retinal function with novel interventions in early AMD. Longitudinal studies are required to identify biomarkers that predict eyes at risk of progression.

Description

Keywords

Citation

Source

Optometry and Vision Science

Book Title

Entity type

Access Statement

License Rights

Restricted until