Test environment running 7.6.6

Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Oral glucose tolerance test to diagnose gestational diabetes mellitus

Abstract

To improve birth outcomes, all pregnant women without known diabetes are recommended for an oral glucose tolerance test (OGTT) to screen for hyperglycaemia in pregnancy (diabetes in pregnancy or gestational diabetes mellitus (GDM)). This narrative review presents contemporary approaches to minimise preanalytical glycolysis in OGTT samples with a focus on GDM diagnosis using criteria derived from the Hyperglycemia and Adverse Pregnancy Outcomes (HAPO) study. The challenges of implementing each approach across a diverse Australian healthcare setting were explored. Many Australian sites currently collect and transport OGTT samples at ambient temperature in sodium fluoride (NaF) tubes which is likely to lead to missed diagnosis of GDM in a significant proportion of cases. Alternative preanalytical solutions should be pragmatic and tailored to individual settings and as close as possible to the preanalytical conditions of the HAPO study for correct interpretation of OGTT results. Rapid centrifugation of barrier tubes to separate plasma could be suitable in urban settings provided time to centrifugation is strictly controlled. Tubes containing NaF and citrate could be useful for remote or resource poor settings with long delays to analysis but the impact on the interpretation of OGTT results should be carefully considered. Testing venous blood glucose at the point-of-care bypasses the need for glycolytic inhibition but requires careful selection of devices with robust analytical performance. Studies to evaluate the potential error of each solution compared to the HAPO protocol are required to assess the magnitude of misdiagnosis and inform clinicians regarding the potential impact on patient safety and healthcare costs.

Description

Citation

Source

Clinical Biochemistry

Book Title

Entity type

Access Statement

License Rights

Restricted until