Test environment running 7.6.6

Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Direct MALDI-TOF MS Identification of Bacterial Mixtures

Loading...
Thumbnail Image

Journal Title

Journal ISSN

Volume Title

Publisher

Abstract

Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is now widely used to characterize bacterial samples for clinical diagnosis, food safety control, environmental monitoring, and so on. However, existing standard approaches are only applied to analyze single colonies purified by plate culture, which limits the approaches to cultivable bacteria and makes the whole approaches time-consuming. In this work, we propose a new framework to analyze MALDI-TOF spectra of bacterial mixtures and to directly characterize each component without purification procedures. The framework is a combination of a synthetic mixture model based on a non-negative linear combination of candidate reference spectra and a statistical assessment by in silico generated spectra via a jackknife resampling. Ninety-seven model bacterial mixture samples and 8 cocultured blind-coded bacterial mixture samples, containing up to 6 strains in varied ratios in each sample, together with a reference database containing the mass spectra of 1081 strains, were used to validate the framework. High sensitivity (>80%, with error rate <5%) was achieved for balanced binary and ternary mixtures. The sensitivity was >60% for balanced quaternary and pentabasic mixtures, and 48%-71% for asymmetric situation, with error rate <5%. The work can facilitate rapid and reliable characterization of bacterial mixtures without purification procedures, which is of practical value in clinical diagnosis, food safety control, environmental monitoring, and so on. The framework can be further applied to many other spectroscopy-based analytics to interpret spectra from mixed samples.

Description

Keywords

Citation

Source

Analytical Chemistry

Book Title

Entity type

Access Statement

License Rights

Restricted until