Test environment running 7.6.6

Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Optimization of Bose-Einstein Condensate Imaging Techniques

Loading...
Thumbnail Image

Date

Authors

Cox, Wesley D

Journal Title

Journal ISSN

Volume Title

Publisher

Abstract

Research into Bose-Einstein condensates is currently a thriving field in physics. Much of the experimental research involves the detection of cold atom clouds under various conditions. Consequently, the fundamental and technical limitations of the imaging techniques and technologies utilized will have a dramatic influence on the results of these experiments. Therefore a detailed analysis of the restrictions on a Bose-Einstein condensate imaging system is overdue and will facilitate further developments in the field due to an increase in the signal to noise ratio; hence a greater level of detail available in experimental images. ¶ The work carried out in this thesis focuses on the properties of absorption imaging techniques, in the quest for an optimized imaging system. Optimization was proposed to be achieved through maximization of the signal to noise ratio by any and all means available. A detailed investigation of the diverse influences on the signal to noise ratio was performed with a focus on eliminating technical restrictions and minimizing fundamental constraints. By studying a 2f - absorption imaging system the maximal signal to noise ratio of 35 was calculated. This corresponded to imaging a cloud of 105 87Rb atoms in a (50 micron) square box with a 31.8MHz detuned, 780nm laser at an intensity of 570W/(m.m) for 35 micro-s. These optimal imaging parameters correspond to our imaging system being limited by the well depth of our detector, not by a fundamental physical process. Furthermore, current experimental noise is identified as the most significant inhibitor to the achievement of an optimized absorption image. ¶ This study represents a first analysis of the quality of current Bose-Einstein condensate imaging techniques and limitations.

Description

Citation

Source

Book Title

Entity type

Access Statement

License Rights

DOI

Restricted until

Downloads