Test environment running 7.6.6

Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Least-squares and maximum-likelihood in computed tomography

Loading...
Thumbnail Image

Journal Title

Journal ISSN

Volume Title

Publisher

Abstract

Purpose: Existing maximum-likelihood (ML) methods in computed tomography usually require significant computing resources to implement, and/or are limited to particular measurement noise models that are representative of the simplest theoretical archetypes. There is an absence of general procedures to produce rapid ML methods that account precisely for the noise model of a given experiment. We investigate a mathematical-computational procedure of producing constrained quadratic optimization reconstruction algorithms that fill this niche, requiring less computing resources than the exact (expectation-maximization) procedures and having comparable performance with least-squares iterative methods. This allows high-fidelity reconstructions to be practically achievable for largely arbitrary noise models. Approach: We identify a systematic mathematical procedure to produce constrained quadratic optimization methods that maximize tomogram likelihood under arbitrary noise models, which are tunable to specific characteristics of the experiment. This procedure is applied to a general theory of mixed Poisson-Gaussian noise in transmission tomography, and to a theory of invertible linear transformations of measurement intensity subject to Poisson noise. We perform tomographic reconstructions of a very highly attenuating two-dimensional object phantom and compare the speed and fidelity of reconstruction with alternative quadratic metrics ( .,"2 - minimization among others). Results: Quantitative metrics reveal that reconstructions under our systematically produced quadratic methods achieved significantly greater reconstruction fidelity with less computation than the optimized conventional, untuned quadratic metrics with a comparable procedure. Conclusion: Constrained quadratic optimization methods appear to apply sufficiently good approximations to achieve a high reconstruction fidelity with a simple quadratic metric amenable to a broad class of minimization methods. These preliminary simulation-based results are very promising and suggest that such methods may be used to produce high-fidelity reconstructions with less computation than many other statistical methods. By design, these quadratic methods are also explicit and quantitative in their description, allowing fine-tuning according to the specific uncertainties and noise model of the experiment. Further research is required to ascertain the full practical potential of these methods.

Description

Citation

Source

Journal of Medical Imaging

Book Title

Entity type

Access Statement

License Rights

Restricted until