Technical developments for computed tomography on the CENBG nanobeam line

dc.contributor.authorGordillo, N
dc.contributor.authorHabchi, C
dc.contributor.authorDaudin, L
dc.contributor.authorSakellariou, Arthur
dc.contributor.authorDelalee, F
dc.contributor.authorBarberet, Ph
dc.contributor.authorIncerti, S
dc.contributor.authorSeznec, H
dc.contributor.authorMoretto, Ph
dc.date.accessioned2015-12-10T23:35:14Z
dc.date.issued2011
dc.date.updated2015-12-10T11:40:01Z
dc.description.abstractThe use of ion microbeams as probes for computed tomography has proven to be a powerful tool for the three-dimensional characterization of specimens a few tens of micrometers in size. Compared to other types of probes, the main advantage is that quantitative information about mass density and composition can be obtained directly, using specific reconstruction codes. At the Centre d'Etudes Nucléaires de Bordeaux Gradignan (CENBG), this technique was initially developed for applications in cellular biology. However, the observation of the cell ultrastructure requires a sub-micron resolution. The construction of the nanobeam line at the Applications Interdisciplinaires des Faisceaux d'Ions en Region Aquitaine (AIFIRA) irradiation facility has opened new perspectives for such applications. The implementation of computed tomography on the nanobeam line of CENBG has required a careful design of the analysis chamber, especially microscopes for precise sample visualization, and detectors for scanning transmission ion microscopy (STIM) and for particle induced X-ray emission (PIXE). The sample can be precisely positioned in the three directions X, Y, Z and a stepper motor coupled to a goniometer ensures the rotational motion. First images of 3D tomography were obtained on a reference sample containing microspheres of certified diameter, showing the good stability of the beam and the sample stage, and the precision of the motion.
dc.identifier.issn0168-583X
dc.identifier.urihttp://hdl.handle.net/1885/69774
dc.publisherElsevier
dc.sourceNuclear Instruments and Methods in Physics Research: Section B
dc.titleTechnical developments for computed tomography on the CENBG nanobeam line
dc.typeJournal article
local.contributor.affiliationGordillo, N, Université Bordeaux 1
local.contributor.affiliationHabchi, C, Université Bordeaux 1
local.contributor.affiliationDaudin, L, Université Bordeaux 1
local.contributor.affiliationSakellariou, Arthur, College of Physical and Mathematical Sciences, ANU
local.contributor.affiliationDelalee, F, Université Bordeaux 1
local.contributor.affiliationBarberet, Ph, Universite de Bordeaux
local.contributor.affiliationIncerti, S, Chimie Nucleaire Analytique et Bioenvironnementale
local.contributor.affiliationSeznec, H, Centre d'Etudes Nucleaires de Bordeaux Gradignan
local.contributor.affiliationMoretto, Ph, Centre d'Etudes Nucleaires de Bordeaux Gradignan
local.contributor.authoruidSakellariou, Arthur, u4010587
local.description.embargo2037-12-31
local.description.notesImported from ARIES
local.identifier.absfor020405 - Soft Condensed Matter
local.identifier.absseo849804 - Management of Solid Waste from Mineral Resource Activities
local.identifier.ariespublicationf2965xPUB2116
local.identifier.citationvolumeOnline
local.identifier.doi10.1016/j.nimb.2011.02.032
local.identifier.scopusID2-s2.0-80053564798
local.type.statusPublished Version

Downloads

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
01_Gordillo_Technical_developments_for_2011.pdf
Size:
669.99 KB
Format:
Adobe Portable Document Format