Test environment running 7.6.6

Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Plasma free metanephrines are superior to urine and plasma catecholamines and urine catecholamine metabolites for the investigation of phaeochromocytoma

Loading...
Thumbnail Image

Date

Authors

Hickman, Peter
Leong, Michelle
Chang, Julia
Wilson, Susan
McWhinney, Brett C

Journal Title

Journal ISSN

Volume Title

Publisher

Taylor & Francis Group

Abstract

Aim: To compare the relative diagnostic efficacy of several different tests used to establish a diagnosis of phaeochromocytoma, in patients with a proven diagnosis of phaeochromocytoma, and in hospital patients with significant disease of other types. Methods: We prospectively compared biochemical markers of catecholamine output and metabolism in plasma and urine in 22 patients with histologically proven phaeochromocytoma, 15 intensive care unit (ICU) patients, 30 patients on chronic haemodialysis and both hypertensive (n=10) and normotensive (n=16) controls. Results: Receiver operating characteristic curves were plotted. At the point of maximum efficiency, plasma free metanephrines showed 100% sensitivity and 97.6% specificity, compared with plasma catecholamines (78.6% and 70.7%), urine catecholamines (78.6% and 87.8%), urine metanephrines (85.7% and 95.1%), and urine hydroxymethoxymandelic acid (HMMA or VMA) (93.0% and 75.8%). All patients with phaeochromocytoma had plasma free metanephrine concentrations at least 27% above the upper limit of the reference range. Only three other patients (two on haemodialysis and one in ICU) had PFM concentrations more than 50% above the upper limit of the reference range. Conclusions: In patients with phaeochromocytoma, plasma free metanephrines displayed superior diagnostic sensitivity and specificity compared with other biochemical markers of catecholamine output and metabolism.

Description

Keywords

Citation

Source

Pathology

Book Title

Entity type

Access Statement

License Rights

Restricted until