Test environment running 7.6.6

Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Breath acetone monitoring by portable Si:WO 3 gas sensors

dc.contributor.authorRighettoni, M.en
dc.contributor.authorTricoli, A.en
dc.contributor.authorGass, S.en
dc.contributor.authorSchmid, A.en
dc.contributor.authorAmann, A.en
dc.contributor.authorPratsinis, S. E.en
dc.date.accessioned2025-03-23T03:27:08Z
dc.date.available2025-03-23T03:27:08Z
dc.date.issued2012en
dc.description.abstractBreath analysis has the potential for early stage detection and monitoring of illnesses to drastically reduce the corresponding medical costs. Here, a portable acetone sensor consisting of flame-deposited and in-situ annealed, Si-doped epsilon-WO 3 nanostructured films was developed. The chamber volume was miniaturized, reaction- and diffusion-limited gas flow rates were identified and sensing temperatures were optimized resulting in low limits of detection and short responses at realistic relative humidities. The acetone content in the breath of test persons was monitored continuously (even in the presence of isoprene) and was in good agreement with state-of-the-art proton transfer reaction - mass spectrometry (PTR-MS). Such chemo-resistive sensors can accurately track acetone concentration and become an alternative to more elaborate breath analysis techniques.en
dc.description.statustrueen
dc.format.extent3en
dc.identifier.isbn9781466562769en
dc.identifier.otherScopus:84865035778en
dc.identifier.urihttps://dspace-test.anu.edu.au/handle/1885/733731095
dc.identifier.urlhttp://www.scopus.com/inward/record.url?scp=84865035778&partnerID=8YFLogxKen
dc.language.isoEnglishen
dc.relation.ispartofseriesTechnical Proceedings of the 2012 NSTI Nanotechnology Conference and Expo, NSTI-Nanotech 2012en
dc.subjectAcetoneen
dc.subjectBreath analysisen
dc.subjectGas sensoren
dc.subjectNanoparticlesen
dc.subjectPTR-MSen
dc.titleBreath acetone monitoring by portable Si:WO 3 gas sensorsen
dc.typeConference contributionen
local.bibliographicCitation.lastpage3en
local.bibliographicCitation.startpage1en
local.contributor.affiliationRighettoni, M.; Swiss Federal Institute of Technology Zurichen
local.contributor.affiliationTricoli, A.; Swiss Federal Institute of Technology Zurichen
local.contributor.affiliationGass, S.; Swiss Federal Institute of Technology Zurichen
local.contributor.affiliationSchmid, A.; Innsbruck Medical Universityen
local.contributor.affiliationAmann, A.; Innsbruck Medical Universityen
local.contributor.affiliationPratsinis, S. E.; Swiss Federal Institute of Technology Zurichen
local.identifier.pure41488208-2a4a-4886-bea7-619f9970e9f7en
local.type.statusPublisheden

Downloads