Test environment running 7.6.6

Cultural advice

The Australian National University acknowledges, celebrates and pays our respects to the Ngunnawal and Ngambri people of the Canberra region and to all First Nations Australians on whose traditional lands we meet and work, and whose cultures are among the oldest continuing cultures in human history.

Aboriginal and Torres Strait Islander peoples are advised that ANU Library collections may include images, names, voices, and other representations of deceased persons.

Material in the collection may contain terms, language or views that reflect the period in which the item was created and may be considered inappropriate today.

Sensitivity and uncertainty analysis of the simulation of 123I and 54Mn gamma and X-ray emissions in a liquid scintillation vial

dc.contributor.authorBignell, L. J.en
dc.contributor.authorMo, L.en
dc.contributor.authorAlexiev, D.en
dc.contributor.authorHashemi-Nezhad, S. R.en
dc.date.accessioned2025-03-27T04:24:33Z
dc.date.available2025-03-27T04:24:33Z
dc.date.issued2010en
dc.description.abstractRadiation transport simulations of the most probable gamma- and X-ray emissions of 123I and 54Mn in a three photomultiplier tube liquid scintillation detector have been carried out. A Geant4 simulation was used to acquire energy deposition spectra and interaction probabilities with the scintillant, as required for absolute activity measurement using the triple to double coincidence ratio (TDCR) method. A sensitivity and uncertainty analysis of the simulation model is presented here. The uncertainty in the Monte Carlo simulation results due to the input parameter uncertainties was found to be more significant than the statistical uncertainty component for a typical number of simulated decay events. The model was most sensitive to changes in the volume of the scintillant. Estimates of the relative uncertainty associated with the simulation outputs due to the combined stochastic and input uncertainties are provided. A Monte Carlo uncertainty analysis of an 123I TDCR measurement indicated that accounting for the simulation uncertainties increases the uncertainty of efficiency of the logical sum of double coincidence by 5.1%.en
dc.description.statustrueen
dc.format.extent8en
dc.identifier.otherScopus:77952958153en
dc.identifier.urihttps://dspace-test.anu.edu.au/handle/1885/733741044
dc.identifier.urlhttp://www.scopus.com/inward/record.url?scp=77952958153&partnerID=8YFLogxKen
dc.language.isoEnglishen
dc.sourceApplied Radiation and Isotopesen
dc.titleSensitivity and uncertainty analysis of the simulation of 123I and 54Mn gamma and X-ray emissions in a liquid scintillation vialen
dc.typeArticleen
local.bibliographicCitation.lastpage1502en
local.bibliographicCitation.startpage1495en
local.contributor.affiliationBignell, L. J.; Australian Nuclear Science and Technology Organisationen
local.contributor.affiliationMo, L.; Australian Nuclear Science and Technology Organisationen
local.contributor.affiliationAlexiev, D.; Australian Nuclear Science and Technology Organisationen
local.contributor.affiliationHashemi-Nezhad, S. R.; University of Sydneyen
local.identifier.citationvolume68en
local.identifier.doi10.1016/j.apradiso.2009.11.051en
local.identifier.purea907f891-dd7e-486c-a082-41a55e37e2d5en
local.type.statusPublisheden

Downloads